Keep command and determine whether the threat continues
The master should activate the ship’s security and emergency procedures, establish bridge and engine-room communications and assign one team to navigation while another assesses damage.
Lookouts must continue scanning air and surface sectors. The projectile may be part of a repeat or combined attack. Nearby small craft, drones, suspicious hails or electronic interference should be reported immediately.
The bridge should establish:
- verified position and time; - ship course, speed and route status; - apparent impact location; - fire, smoke, flooding or list; - injuries and missing persons; - propulsion, steering and electrical condition; - communications and navigation availability; - cargo or bunker involvement; and - whether another threat is approaching.
A rapid manoeuvre may be needed, but it must account for traffic, sea room, route limits and damaged systems. The ship should not turn blindly based on a GNSS position that may be compromised.
The master should maintain authority over both the security and casualty response. Shore questions must not distract the bridge.
Treat life safety before explaining the weapon
Crew accountability and medical triage come first. Personnel should move away from the impact area, exposed decks and windows while essential responders use appropriate protective equipment.
The team should check for blast, burns, smoke inhalation, fragmentation and hearing injury. A crew member who appears unhurt may still need later assessment.
The impact zone may contain unstable structure, hot metal, toxic smoke, damaged electrical equipment or unexploded material. Entry should be controlled.
If the bridge is affected, the ship should use the designated emergency conning position where available. If the engine room is involved, remote shutdowns, ventilation and fuel isolation should follow the emergency plan.
The casualty message should say “crew check in progress” until accountability is complete. An early report of no injuries should be corrected visibly if the medical picture changes.
Attack fire without losing watertight integrity
The correct firefighting method depends on the affected space, cargo and fuel. The crew should follow the vessel’s fire-control plan, emergency procedures and cargo-specific guidance.
For an engine-room fire, the team may need to stop ventilation, close dampers, isolate fuel and electrical sources and decide whether fixed extinguishing media are required. Releasing a fixed system has major machinery and evacuation consequences and must follow the approved procedure.
A deck or cargo fire may require boundary cooling, cargo isolation and attention to vapour or dangerous-goods hazards. Water can worsen some cargo reactions or stability problems.
The crew should check adjacent compartments, cable routes, penetrations and tanks. A small visible fire can conceal heat, structural cracks or a bunker leak.
Firefighting parties should remain protected from another strike. Personnel should not crowd the impact side, and relief should be organized if the response becomes prolonged.
IMO’s EmS Guide says initial fire and spillage actions involving dangerous goods should follow the shipboard emergency plan and cargo-specific schedules.
Check hull, stability and pollution
The damage-control team should identify holes, deformation, flooding, tank-level changes and unusual list or trim. Soundings and remote indicators should be cross-checked because sensors may be damaged.
Watertight doors, vents and openings should be secured as appropriate. Counter-flooding should not be improvised without stability analysis and command approval.
Cargo or bunker release must be reported promptly. The absence of a visible slick is not proof that no pollution occurred. Night, fire and sea conditions can obscure it.
The company’s emergency team can support stability calculations using the verified damage description. The ship should preserve draft, tank and ballast data before changes where time permits.
A damaged shell plate above the waterline can become submerged after list, speed change or weather. Continued movement may increase stress around a fracture.
The master should identify the safest achievable condition rather than assume that remaining underway is always better.
Isolate suspected unexploded ordnance
The May 2026 Hormuz guidance identifies unexploded ordnance as a hazard after missile or drone strikes. Any unfamiliar fragment, embedded object or device should be treated cautiously.
Crew should not touch, move, wash down or photograph it from close range for curiosity. The area should be cleared, access controlled and ignition or radio precautions followed under competent authority advice.
The master should report the object’s location and appearance through security channels and request explosive-ordnance support. Photographs from a protected position may assist if authorities request them.
An object can be dangerous even if it appears inert. Structural movement, heat, vibration or handling may change its condition.
UXO presence can affect firefighting, towing, port entry, survey and refuge. The company must tell authorities and salvors before personnel approach the ship.
Evidence preservation is secondary to preventing another casualty.
Report facts and request the right assistance
The first incident report should include ship identity, UTC, verified position, course and speed, observable event, impact location, casualties, damage, pollution, action and assistance needed.
Use “unknown projectile” unless competent evidence supports a more specific description. A crew impression should be labeled as such.
For US-flagged ships, current MARAD guidance requires immediate SSAS activation and contact with the Fifth Fleet Battle Watch and UKMTO following an attack or incident. Other ships follow their flag and approved plans.
Assistance requests should be specific: medical evacuation, firefighting, tug, salvage, pollution response, explosive-ordnance support or protected routing. Authorities can prioritize better than when the message says only “damaged.”
The company should notify flag, class, insurers and charterers through controlled channels. The bridge should receive one consolidated shore contact.
Updates should be timestamped and correct earlier uncertainty rather than overwrite it.
Decide whether to continue, seek refuge or abandon
Continuing to the next port may be safer than stopping in an exposed sector, but only if fire is controlled, structural and machinery condition are understood, the crew can operate safely and the destination will accept the ship.
Seeking a place of refuge requires early coastal-State communication. IMO Resolution A.1184(33) says the master or salvor should contact the appropriate maritime assistance service, inform the company and provide ship, cargo, bunker, persons-on-board and incident details.
A port may need time to assess fire, pollution, UXO and berth consequences. The ship should not conceal relevant damage to secure entry.
Abandonment is a grave decision. The master should consider fire, flooding, stability, rescue availability, sea conditions and continuing attack. Lifeboats can be exposed to the same threat and may be harder to locate under electronic disruption.
The decision and triggers should be communicated clearly to crew and authorities. Commercial pressure to save schedule or hull cannot override life safety.
Preserve evidence and commercial rights
Once stable, the ship should preserve VDR, radar, ECDIS, CCTV, communications, alarms, machinery trends, photographs and witness accounts. Original fragments should remain under controlled authority handling.
The incident file should separate observed facts, crew assessments, authority conclusions and later forensic findings. Public attribution should wait for competent evidence.
Owners should issue policy notices and preserve claim documentation without conceding cause or liability. Hull, war, P&I, pollution, cargo and loss-of-hire interests may require different information.
Charterers need verified status, deviation and cargo consequences. A ship reaching port under its own power does not prove seaworthiness or end the delay.
ZeaClub can coordinate the damage checklist, source-stamped reports and notification workflow. It cannot diagnose structure, identify a weapon or authorize continued navigation.
Commercial conclusion
After a projectile strike, the crew should manage consequences before theories.
The master keeps command, protects people, controls fire and flooding, verifies navigation and machinery, isolates suspected UXO and reports observable facts. Class, flag, coastal authorities, salvors and insurers then support the decision to continue, seek refuge or abandon.
Calling the projectile “unknown” is not evasive. It protects the integrity of the response until evidence establishes more, while the ship concentrates on the facts that determine survival.
This article distinguishes verified source material from ZeaClub analysis, recommendations, forecasts and hypothetical scenarios.
Sources
- UKMTO, recent incident warningsAccessed 2026-11-19
- UKMTO, weekly VRA overview ending 13 November 2026Accessed 2026-11-19
- Industry Guidance on the Safe Management of Vessel Transit through the Strait of Hormuz, May 2026Accessed 2026-11-19
- International Maritime Organization, EmS GuideAccessed 2026-11-19
- International Maritime Organization, Resolution A.1184(33) on places of refugeAccessed 2026-11-19
- US Maritime Administration, Advisory 2026-011Accessed 2026-11-19